Guide To Building Green
Cool Roof Rating Council

Cool Roof Rating Council (CRRC)

Mission

  • Independent organization
  • Established a method for reporting creditable reflective properties of roof surfaces
  • Registers laboratories to do the testing
  • Maintains list of registered manufacturers and product reflective properties

Test Methods CRRC-1

Test Methods

  • Reflectivity
    • ASTM E 908
    • ASTM E 1918
    • ASTM C 1549
  • Emittance
    • ASTM C 1371

Test Procedures

  • Inital
    • Samples submitted to accredited laboratory for testing
    • Materials from two (2) lots shall be supplied
  • Weathered Samples
    • From same materials submitted for initial testing
    • Sample size is 24 sq in mounted on plywood
    • Material is sent to Accreditied Lab
    • Accredited Lab will send materials to Weathering Farm lab
    • Weather Farm Lab will return the samples to accredit lab after three (3) years of testing
    • Accredited Lab reads final values for reflective and emittance
  • Carlisle Listed Products

 

Carlisle Listed Products

Product Reflectance Emittance
Sure-Weld White
.79
.90
Sure-Weld Tan
.66
.89
Sure-Weld Gray
.26 
 .89
Sure-White EPDM 
.76
.90
Sure Seal EPDM
.12
.87

CRRC Labeling

  • CRRC label can only be used on products tested to CRRC-1